<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\NVSStyleSheet.xsl"?>
<Parameter>
<ParameterFamily>media</ParameterFamily>
<LongName>
tolerance_limit
</LongName>
<Name>
ltol
</Name>
<AppliesTo>
<UnnumberedList>
<ListItem><TextApplies>Green</TextApplies></ListItem>
</UnnumberedList>
</AppliesTo>
<Description>
<DescriptionText><text>
Absolute maximum deviation from the target exposure allowable in a calibrated
stroke.  The tolerance will be increased from "media stol" until this tolerance
limit is exceeded. Normally, this parameter is not changed from the default
value.  Making this parameter too small may lead to the
firmware reporting the "Can't flatten stroke" error message.  Making this
parameter too large may lead to imaging artifacts from non-flat strokes.
</text></DescriptionText>
</Description>
<Type>
real
</Type>
<Default>
<UnnumberedList>
<li>1</li>
</UnnumberedList>
</Default>
<Range>
<UnnumberedList>
<li>0.0 to 32.0 [%]</li>
</UnnumberedList>
</Range>
<ArraySize>
</ArraySize>
<Notes>
<DescriptionText><text>
</text></DescriptionText>
</Notes>
<Partition>
cal
</Partition>
<SeeAlso>
<UnnumberedList>
<li><Link><LinkAddress>../nvs/media_cal_stol.xml</LinkAddress><LinkTitle>NVS: media stol</LinkTitle></Link></li>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<li><Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link></li>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:37:12 2008 PST
</Updated>
<Links>
</Links>
</Parameter>